Species:
Human
Type:
Sandwich
Duration:
3.5h
Detection:
Chemiluminescence
Sensitivity:
37.5pg/mL
Range:
62.5~4000pg/mL
Adding to cart… The item has been added

Human AXIN2 (Axis Inhibition Protein 2) CLIA Kit | G-EC-00509 | Gentaur Clia Kits

Target Species: Human

Type: Sandwich

Assay Time: 3.5h

Detection Type: Chemiluminescence

Sensitivity: 37.5pg/mL

Detection Range: 62.5~4000pg/mL

UniProt ID:

Target Name: AXIN2

Target Synonym: Axin-2, Axil, Conductin, ODCRCS, Axin-like protein

Tested Sample Types: Serum, plasma and other biological fluids

Test Principle: This CLIA kit uses the Sandwich-CLIA principle. The micro CLIA plate provided in this kit has been pre-coated with an antibody specific to Human AXIN2. Standards or samples are added to the micro CLIA plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human AXIN2 and Avidin-Horseradish Peroxidase (HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human AXIN2, biotinylated detection antibody and Avidin-HRP conjugate will appear fluorescence. The Relative light unit (RLU) value is measured by the Chemiluminescence immunoassay analyzer. The RLU value is positively associated with the concentration of Human AXIN2. You can calculate the concentration of Human AXIN2 in the samples by comparing the RLU value of the samples to the standard curve.

Specificity: This kit recognizes Human AXIN2 in samples. No significant cross-reactivity or interference between Human AXIN2 and analogues was observed.

Application: This CLIA kit applies to the in vitro quantitative determination of Human AXIN2 concentrations in Serum, plasma and other biological fluids.

Research Areas: Cancer, Cell Biology, Epigenetics and Nuclear Signaling, Neuroscience, Stem cells

Storage: An unopened kit can be stored at 2-8℃ for 1 month. If the kit is not supposed to be used within 1 month, store the items separately according to the storage table in the manual once the kit is received.