Human ApoC4 (Apolipoprotein C4) CLIA Kit | G-EC-00480

(1 review) Write a Review
€223.44 - €3,472.56
SKU:
G-EC-00480
Availability:
3 to 5 Working Days
Species:
Human
Type:
Sandwich
Duration:
3.5h
Detection:
Chemiluminescence
Sensitivity:
4.69pg/mL
Range:
7.81~500pg/mL
Adding to cart… The item has been added

Human ApoC4 (Apolipoprotein C4) CLIA Kit | G-EC-00480 | Gentaur Clia Kits

Target Species: Human

Type: Sandwich

Assay Time: 3.5h

Detection Type: Chemiluminescence

Sensitivity: 4.69pg/mL

Detection Range: 7.81~500pg/mL

UniProt ID:

Target Name: ApoC4

Target Synonym: Apolipoprotein C-IV, apolipoprotein C4, APOC4, APO-CIV, APOC-IV

Tested Sample Types: Serum, plasma and other biological fluids

Test Principle: This CLIA kit uses the Sandwich-CLIA principle. The micro CLIA plate provided in this kit has been pre-coated with an antibody specific to Human ApoC4. Standards or samples are added to the micro CLIA plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human ApoC4 and Avidin-Horseradish Peroxidase (HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human ApoC4, biotinylated detection antibody and Avidin-HRP conjugate will appear fluorescence. The Relative light unit (RLU) value is measured by the Chemiluminescence immunoassay analyzer. The RLU value is positively associated with the concentration of Human ApoC4. You can calculate the concentration of Human ApoC4 in the samples by comparing the RLU value of the samples to the standard curve.

Specificity: This kit recognizes Human ApoC4 in samples. No significant cross-reactivity or interference between Human ApoC4 and analogues was observed.

Application: This CLIA kit applies to the in vitro quantitative determination of Human ApoC4 concentrations in Serum, plasma and other biological fluids.

Research Areas: Cardiovascular, Metabolism, Signal transduction

Storage: An unopened kit can be stored at 2-8℃ for 1 month. If the kit is not supposed to be used within 1 month, store the items separately according to the storage table in the manual once the kit is received.

Human ApoC4 (Apolipoprotein C4) CLIA Kit DataSheet

1 Review Hide Reviews Show Reviews

  • 5
    Highly appreciateable

    Posted by Kaiden on 28th Dec 2021

    the way they are handling their management and shipping with quality is highly appreciateable