Human ARHGDIα (Rho GDP Dissociation Inhibitor Alpha) CLIA Kit | G-EC-00495

(1 review) Write a Review
€223.44 - €3,472.56
SKU:
G-EC-00495
Availability:
3 to 5 Working Days
Species:
Human
Type:
Sandwich
Duration:
3.5h
Detection:
Chemiluminescence
Sensitivity:
18.75pg/mL
Range:
31.25~2000pg/mL
Adding to cart… The item has been added

Human ARHGDIα (Rho GDP Dissociation Inhibitor Alpha) CLIA Kit | G-EC-00495 | Gentaur Clia Kits

Target Species: Human

Type: Sandwich

Assay Time: 3.5h

Detection Type: Chemiluminescence

Sensitivity: 18.75pg/mL

Detection Range: 31.25~2000pg/mL

UniProt ID:

Target Name: ARHGDIα

Target Synonym:

Tested Sample Types: Serum, plasma and other biological fluids

Test Principle: This CLIA kit uses the Sandwich-CLIA principle. The micro CLIA plate provided in this kit has been pre-coated with an antibody specific to Human ARHGDIα. Standards or samples are added to the micro CLIA plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human ARHGDIα and Avidin-Horseradish Peroxidase (HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human ARHGDIα, biotinylated detection antibody and Avidin-HRP conjugate will appear fluorescence. The Relative light unit (RLU) value is measured by the Chemiluminescence immunoassay analyzer. The RLU value is positively associated with the concentration of Human ARHGDIα. You can calculate the concentration of Human ARHGDIα in the samples by comparing the RLU value of the samples to the standard curve.

Specificity: This kit recognizes Human ARHGDIα in samples. No significant cross-reactivity or interference between Human ARHGDIα and analogues was observed.

Application: This CLIA kit applies to the in vitro quantitative determination of Human ARHGDIα concentrations in Serum, plasma and other biological fluids.

Research Areas: Cancer, Signal transduction

Storage: An unopened kit can be stored at 2-8℃ for 1 month. If the kit is not supposed to be used within 1 month, store the items separately according to the storage table in the manual once the kit is received.

Human ARHGDIα (Rho GDP Dissociation Inhibitor Alpha) CLIA Kit DataSheet

1 Review Hide Reviews Show Reviews

  • 5
    higher quality

    Posted by Brooks on 28th Dec 2021

    I ordered few anti biotics from here,with full satisfaction. I will definitely recommend this!